Practice Free NS0-184 Exam Online Questions
What are two ways to identify an AFF All SAN Array system? (Choose two.)
- A . Use the san config show CLI command.
- B . View the ONTAP System Manager system nodes.
- C . Use the cluster image show CLI command.
- D . View the ONTAP System Manager cluster settings.
A customer must create VLAN 599 tagging on physical port e0g from cluster node filer1-01.
What is the name of the new VLAN interface?
- A . e0g-vlan599
- B . vlan599-e0g
- C . vl599-e0g
- D . e0g-599
Click the Exhibit button.
A customer wants to replace their ONTAP cluster CN1610 switches with Cisco Nexus 3132Q-V switches. They want to perform a non-disruptive upgrade.
Referring to the exhibit, which cable will be required to non-disruptively migrate to the new switches?
- A . a 10GbE SFP+ to SFP+ cable
- B . a 100GbE QSFP28+ to 4x25GbE SFP28+ cable
- C . a 40GbE QSFP+ to QSFP+ cable
- D . a 40GbE QSFP+ to 4x10GbE SFP+ cable
After you install an AFF A700 2-node cluster with DS224C shelves, Config Advisor reports that your SAS cabling is in mixed-path HA. You expected the SAS cabling be in quad-path HA.
You physically verify the LED status on the controllers and the shelves and notice no irregularities. However, a reboot of the SAS expander does not change the output.
In this scenario, what should you do next?
- A . Open a case with NetApp Support and turn off the disk shelves until the issue is solved.
- B . Disconnect the disk shelves from the controller and run Config Advisor again.
- C . Re-seat the SAS IO modules of the affected AFF A700 controller.
- D . Use multipath HA because it is the only cabling supported on an AFF A700 controller.
You want to enable secure communication with the SP or BMC through CA-signed certificates.
Which two certificate types must be installed in this scenario? (Choose two.)
- A . cluster certificate
- B . server certificate
- C . root CA certificate
- D . ONTAP certificate
You are asked to installed a new cluster with six FAS8060 nodes. While running Config Advisor, you determine that there is a newer firmware version for 16 HDDs.
How should this situation be handled?
- A . Prior to leaving the site, advise the customer that firmware is included with the version of ONTAP they selected.
- B . Unless the customer advises otherwise, upgrade the firmware on the HDDs to correct the Config Advisor error.
- C . Unless the customer advises otherwise, leave the firmware alone and document the version of ONTAP being used to explain the issue.
- D . Prior to leaving the site, confirm the version of ONTAP that the customer wanted installed to correct the Config Advisor error.
What are two requirements for a 6-node cluster? (Choose two.)
- A . network connectivity from the cluster to the customer’s infrastructure
- B . dedicated switches for the cluster interconnect
- C . SAN connectivity from the cluster to the customer’s infrastructure
- D . dedicated switches for the cluster management
Click the Exhibit button.
You are installing a new AFF All SAN Array A700 HA pair.
Referring to the exhibit, which IP address would have been used to join node 02 to the cluster during setup?
- A . 192.168.0.112
- B . 169.254.212.198
- C . 169.254.145.151
- D . 192.168.0.101
Your customer plans to expand a 2-node FAS2750 switched cluster with two new controllers.
In this scenario, which two prerequisites should you examine in advance? (Choose two.)
- A . Verify that the hard drives of the new controllers are compatible with the old controllers.
- B . Verify that the existing cluster has a minimum 10 GB of free space for root volumes.
- C . Verify that the existing switches support the additional controllers.
- D . Verify that the platform of the new controllers can be mixed with the cluster’s existing controllers.
In a 4-node cluster, what is function of the HA interconnect? (Choose the best answer.)
- A . It provides the ability to relocate the aggregate ownership.
- B . It provides the ability to synchronize the cluster configuration.
- C . It provides nondisruptive operations and fault tolerance.
- D . It provides the ability to migrate a data aggregate to any node in the cluster.