Practice Free D-VXR-OE-23 Exam Online Questions
When deploying a VxRail cluster with an internal DNS server, where is the DNS server located?
- A . VxRail Manager VM
- B . vSphere Distributed Switch
- C . vCenter Server Appliance
- D . Standalone VM
What is required to setup vSAN HCI Mesh?
- A . Latency of 5 milliseconds and network redundancy
- B . vSAN Enterprise License and 1 Gbps Networking
- C . Latency of 10 milliseconds and bandwidth of 10 Gbps
- D . vSAN Advanced License and bandwidth of 25 Gbps
C
Explanation:
To set up vSAN HCI Mesh, a latency of 10 milliseconds and a bandwidth of 10 Gbps are required. vSAN HCI Mesh allows vSAN clusters to share storage resources over a network. Ensuring low latency and high bandwidth is crucial for maintaining performance and reliability in a hyper-converged infrastructure (HCI) environment, which vSAN HCI Mesh facilitates.
Reference: VMware vSAN HCI Mesh Requirements: VMware vSAN HCI Mesh
A VxRail cluster needs to be moved to a new rack in the datacenter. During this process, the entire cluster will be temporarily shut down.
Which Maintenance Mode option is the best fit?
- A . Protected maintenance mode
- B . Ensure accessibility
- C . Full data migration
- D . No data migration
A customer wants to manage multiple VxRail clusters from one vSphere client instance. They would like to avoid purchasing additional licensing.
Which option meets the customer needs?
- A . multiple VxRail clusters using Enhanced Linked Mode
- B . multiple VxRail clusters using CloudIQ.
- C . multiple VxRail clusters using a single external vCenter
- D . multiple VxRail clusters using SaaS multi-cluster management
An environment has two VxRail clusters with the following hardware configuration:
– Cluster-A is using FTT = 2 and FTM = Erasure Coding
– Cluster-B is using FTT = 2 and FTM = Mirroring
A 100 GB VM is planned to be vMotioned from Cluster-A to Cluster-B.
How much more vSAN capacity is consumed in Cluster-B than in Cluster-A?
- A . 0 GB; consumption is unchanged
- B . 100 GB
- C . 150 GB
- D . 167 GB
Which VxRail network supports Link Aggregation?
- A . VxRail System VMs
- B . vSAN
- C . ESXi Management
- D . Private Management
An administrator needs to place a node in maintenance mode They want to ensure vSAN does not start rebuilding absent components during the time it takes for maintenance to be completed
What would allow the administrator to achieve this?
- A . Temporarily disable components ^synchronization.
- B . Temporarily set FTT=0 in vSAN Storage Policy.
- C . Increase vSAN Object repair timer
- D . Increase durability component lifetime.
C
Explanation:
To ensure that vSAN does not start rebuilding absent components while a node is in maintenance mode, an administrator should increase the vSAN Object repair timer. The Object repair timer controls the delay before vSAN initiates the rebuild of absent components. By increasing this timer, the administrator can ensure that maintenance can be completed without triggering unnecessary rebuilds, reducing the load on the system and preventing potential data redundancy issues.
Reference: VMware vSAN Configuration Guide: vSAN Configuration Guide
What is the purpose for deploying VxRail with more than one vSphere distributed switch?
- A . vMotion redundancy
- B . vSAN redundancy
- C . link aggregation
- D . network segmentation
What is the purpose for deploying VxRail with more than one vSphere distributed switch?
- A . vMotion redundancy
- B . vSAN redundancy
- C . link aggregation
- D . network segmentation
If automatic rebalancing is not configured, when does vSAN perform reactive rebalancing?
- A . capacity utilization nears or exceeds 85%
- B . capacity utilization nears or exceeds 75%
- C . capacity utilization nears or exceeds 90%
- D . capacity utilization nears or exceeds 80%