Practice Free 5V0-22.23 Exam Online Questions
Which two considerations should an architect make when designing a HCI Mesh solution with VMware vSAN and VMware vSphere High Availability (HA)? (Choose two.)
- A . If vSphere HA is to work with HCI Mesh, Datastore with All Paths Down (APD) must be configured to Power off and restart VMs.
- B . If vSphere HA is to work with HCI Mesh, Datastore with Permanent Device Loss (PDL) must be configured to Power off and restart VMs.
- C . A minimum of three nodes are required within the client cluster for vSphere HA to work.
- D . A client cluster can mount up to ten remote datastores from one or more vSAN server clusters.
- E . A server vSAN cluster can serve its local datastore up to five client vSAN clusters.
The administrator has successfully deployed a vSAN Stretched Cluster and needs to ensure that any virtual machines that are created are placed in the appropriate site.
Which two steps are needed to complete this task? (Choose two.)
- A . Put the VMs in a vSphere DRS group.
- B . Create a storage policy that includes site affinity rules and apply to VMs.
- C . Create a single VM/Host group across both sites.
- D . Create VM/Host groups for the two sites.
- E . Put the VMs in the correct VM group.
An administrator is tasked to create a Kerberos secured NFS v4.1 file share.
Which information is minimally required during the configuration of the File Service?
- A . Active Directory Domain, Organizational Unit, User Account, Password
- B . Kerberos Server, User Account, Password
- C . Organizational Unit, User Account. Password
- D . Active Directory Domain, User Account, Password
A vSAN Administrator has a cluster of six vSAN nodes. The vSAN datastore was 55% utilized, and due to a power outage, one node was lost. The vSAN administrator needs to resolve the storage policy compliance for the virtual machines on RAID-5.
Which action, if any, needs to be taken to meet this goal?
- A . No action is needed since vSAN automatically rebuilds the objects.
- B . The one failed node must be restored.
- C . Trigger vSAN object repair from ESXCLI.
- D . Change the RAID-5 FTT from 2 to 1.
A vSAN administrator would like to configure Cloud Native Storage with File Volumes with vSAN 7.0.
Which two requirements must be met? (Choose two.)
- A . Use a compatible version of CSI driver.
- B . vSAN Cloud Native Storage is only available with RDMA-based networking.
- C . Enable and configure vSAN File Services on the vSAN cluster.
- D . The vSAN cluster must be connected to an external NFS storage to provide File Volume services.
- E . The cluster must have a vSAN on-disk format version 5 for Cloud Native Storage to be available.
A vSAN administrator is tasked with changing the stripe width for a specific storage policy on a vSAN 7.0 GA cluster in order to improve performance, but the component distribution desired is across hosts, not just across a disk group.
Which action, if any, should the administrator take to complete this task?
- A . No action is needed.
- B . Upgrade vSAN to 7.0 Update 1.
- C . Enable vSAN Performance Services in order to increase the number of Stripes available across hosts.
- D . Change the default policy to force provisioning to spread components across hosts.
A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources.
Which two strategies should the vSAN administrator use to achieve this goal? (Choose two.)
- A . RAID-5/FTT=1
- B . vSAN stretched cluster
- C . Specify fault domains
- D . RAID-6/FTT=2
- E . 2-node configuration
An application refactor requires significant storage that is being added for logs stored on a VM vDISK. The application VMs runs on a dedicated vSAN enabled vSphere Cluster with custom CPUs and RAM, and therefore, cannot vMotion to another vSAN enabled cluster.
The administrator needs a vSAN feature that can be used to allocate additional storage from another vSAN enabled vSphere cluster to this vSAN enabled Cluster.
Which vSAN feature should be used for this purpose?
- A . vSAN Replication
- B . vSAN File Services
- C . vSAN HCI Mesh
- D . vSAN Stretched Clusters